Secondary Suite Requirements in Metro Vancouver: Fire Separation, Sound, Exits, Ceiling Height and Permits Under the BC Building Code 2024

By Costar Construction

Frequently asked questions

How much fire separation does a basement suite need in Burnaby or Richmond?

Under Article 9.10.9.16 of the BC Building Code 2024, the rating depends on the smoke alarms. It is 45 minutes if the alarms are not interconnected, 30 minutes if an extra photo-electric alarm in each unit is interconnected, and 15 minutes if every alarm in the house is photo-electric and interconnected. A fully sprinklered house needs no rating. Burnaby and Richmond both repeat these three levels in their suite guides.

What is the minimum ceiling height for a legal suite in an existing BC house?

In a new house, Table 9.5.3.1 of the BC Building Code 2024 asks for 2.1 metres over a set area of each room. When a suite is added to an existing house, Table 1.1.1.1.(6) allows 1.95 metres over that area, and 1.85 metres of clear height under beams and ducts. Ask your city which option applies to your project.

Do the two units in a house with a suite need separate furnaces in BC?

The BC Building Code 2024 does not require two systems. If one heating or ventilation system serves both units, Article 9.32.3.2 requires it to stop spreading smoke when a smoke detector in the ducts sends a signal, and ducts through a fire separation need fire dampers. Burnaby's suite guide says a separate system for the suite is preferable.

How soundproof does the wall or ceiling between a suite and the main house have to be?

Article 9.11.1.1 of the BC Building Code 2024 accepts three options for a house with a secondary suite. One is sound-absorbing material in the joist and stud spaces, resilient channel on one side and 12.7 mm gypsum board on ceilings and both sides of walls. The others are an assembly rated at least STC 43, or a tested assembly of at least ASTC 40.

Can a legal secondary suite be sold separately from the house in BC?

No. The BC Building Code 2024 defines a secondary suite as one of two dwelling units that form a single real estate entity. Burnaby's guide says a suite cannot be subdivided by strata plan, and Richmond's bulletin says secondary suites are not permitted to be stratified.

Can I do the wiring or plumbing myself for a suite in Burnaby?

No. Burnaby's Secondary Suite Informational Guide, revised November 15, 2024, says homeowners are not permitted to carry out sub-trade work in a dwelling with a secondary suite. Licensed electrical, plumbing and gas contractors take out their own permits after the building permit is issued. Ask the City before you start any work yourself.

Does the BC Building Code apply to a secondary suite in the City of Vancouver?

The Province's BC Codes page says the BC Codes do not apply in the City of Vancouver, which has its own building bylaw. Vancouver's permit pages refused our requests on September 29, 2026, so confirm the suite rules for your address with the City's Development and Building Services Centre.

Is there a minimum size for a secondary suite in Richmond or Burnaby?

Yes, and each city sets its own. Richmond's bulletin BUILDING-22, revised July 28, 2025, sets 33.0 square metres in a single detached house and 25.0 in small-scale multi-unit housing, with a cap of 40 percent of the unit and 120 square metres. Burnaby's guide sets a minimum of 32.52 square metres. These figures are as of September 2026, so confirm them with the city.